5320A - Fluke United States Sales


Please Contact Us to Order to offer best price and delivery time for Fluke - 5320A Multifunction Electrical Tester Calibrator number, also you may ask some other model number is well. We can offer best price, and delivery time with wide products distribution network in United States Industrial products Market. 

WE SELL ONLY ORIGINAL AND NEW PRODUCTS!

Our company is not an authorized distributor and manufacturer's representative of the brands shown on the website. Private brand names shown on this site and trademarks are the property of their respective owners

Important note: Although we Fluke - Products are Onrion LLC not an authorized dealer. All rights are reserved by the manufacturers and their official partners. 

Where can I buy 5320A by Fluke in United States?

You can purchase 5320A by Fluke from Onrion LLC. We serve customers across United States, offering competitive prices and reliable service.

What is the price of the 5320A?

For customized pricing and availability, please fill out our contact form or give us a call. We are dedicated to providing solutions that align with your specific requirements.

Who is the official distributor or seller of Fluke in United States?

While we are not the official distributor or seller of Fluke in United States, we source our products from reliable channels and offer you original Fluke equipment at competitive prices.

How can I access 5320A catalogs, user manuals, technical documents, and PDFs?

You can access catalogs, user manuals, and technical documents for 5320A on our website. Visit our resources section or contact us directly for specific documents.

Do you provide technical support for 5320A?

While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.

BRAND Fluke
Product 5320A
Description Multifunction Electrical Tester Calibrator
Internal code ONR4537642
Weight 1
Technical specification Precision Low Resistance Source Ranges: 100 mΩ to 10 kΩ Resolution: 3 ½ digits (continuously variable) Maximum Current Ranges: 5 mA to 400 mA Modes: 2-Wire and 4-Wire Best 1 Year Specification: ± 0.2 % of setting High Resistance Source (High voltage) Ranges: 10 kΩ to 100 GΩ Resolution: 4 ½ digits (continuously variable to 10 GΩ) Maximum Voltage Ranges: 55 Vpk to 1575 Vpk Best 1 Year Specification: ± 0.2 % of setting Resistance Multiplier Adapter¹ (for high resistance source) Resistance Ranges: 350 MΩ to 10 TΩ Maximum Test Voltage: 5500 V dc Best 1 Year Specification: Uncertainty of 5320A resistor to be multiplied ± 1 % of displayed value Low Resistance Source (High current) Ranges: 25 mΩ to 1.8 kΩ, 16 values Maximum Current Ranges: 0.025 A to 30 A (continuous) 0.15 A to 40 A (short-term) Best 1 Year Specification: ± 5 mΩ of setting Loop Compensation: 0 to 10 Ω (Scan Mode) 0 to 2 Ω (Active Comp Mode) Loop Compensation Specification: ± 1 % + 15 mΩ (Scan and active comp Mode) Active Loop Compensation available on 5320A/VLC only Line Leakage Current Source Ranges: 0.1 mA to 30 mA Resolution: 10 uA of setting Test Voltage Ranges: 10 to 250 V Modes: Passive, Differential, Substitute, Active Best 1 Year Specification: ± 0.3% + 1 uA of setting Residual Current Device Trip Current Ranges: 3 to 3000 mA Trip Current Modes: 0.5xI, 1xl, 1.4xI, 2xI, and 5xI Best 1 Year Trip Current Specification: ± 1 % rms Trip Time Ranges: 10 to 5000 ms Best 1 Year Trip Time Specification: ± 0.25 ms Multimeter Voltage Ranges: 0 to 1100 V ac rms or dc Voltage Resolution: 4 ½ digits Best 1 Year Voltage Specification: ± 0.15% of reading + 5 mV Current Ranges: 0 to 30 A ac rms or dc Current Resolution: 4 ½ digits Best 1 Year Current Specification: ± 0.15% of reading + 0.15 mA Phantom Power: 0 to 33 kVA Phantom Power Resolution: 3 digits Best 1 Year Power Specification: √((V)² + (I)²) Hipot Leakage Current Measurement Mode (Multimeter mode) Current Range 0 to 300 mA acrms or cc Current Resolution 4 ½ digits Best 1 Year Specification ± 0.2% of reading + 0.21 mA Hipot Timer Measurement Mode (Multimeter mode) Timer Measurement Range 0.1 to 999 s Timer Resolution 1 ms Best 1 Year Specification 0.02% + 2 ms (dc) 0.02% + 20 ms (ac) 10 kV Divider Adapter¹ (for multimeter input) Voltage Ranges: 0 to 10 kV ac peak or dc Voltage Divider Ratio: 1000:1 Best 1 Year Specification: ± 0.3 % of reading + 5 V dc ± 0.5 % of reading + 5 V ac (50 or 60 Hz) 40 kV Probe² (for multimeter input) Accessory Voltage Ranges: 0 to 40 kV ac peak or dc Voltage Divider Ratio: 1000:1 Best 1 Year Specification: ± 0.5 % of reading + 10 V dc ± 0.5 % of reading + 10 V ac (50 or 60 Hz) Voltage Calibrator Source (5320A/VLC only) Ranges: 3 to 600 V ac or dc Voltage Resolution: 4 digits Frequency: 40 to 400 Hz Frequency Resolution: 3 digits Maximum Burden Current: 500 mA (ac) 5 mA (dc) Best 1 Year Current Specification: ± 0.1 % of setting + 9 mV

No documents...

More products of Fluke

4709934 / Fluke 369FC

Digital current clamp data logger

Tix 1000

Thermal-infrared Camera

87V/E2 Kit

Digital Multimeter

3150-4

Multi-Hole Dry Block Furnace Insert

Fluke 233

handheld multimeter

T6-600/EU

handheld multimeter

Art.Nr. 10.172 (Impulse 7010)

Defibrillator Selectable Loads Analyzer

Art.Nr. 10.875 Model: ProSim 8P

Vitalparameter Simulator

721-1610

PRESSURE CALIBRATOR

P/N: 2547153, Type: 718 300G

Pressure Calibrator

80PK-1

Bead Probe

80BK-A

THERMOCOUPLE

17B ERTA

DIGITAL MULTIMETER

4489229, Fluke 805FC

Vibration meter